# smartctl -a /dev/sdb smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-8-amd64] (local build) Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Momentus 7200.5 Device Model: ST9500423AS Serial Number: 6WR093N3 LU WWN Device Id: 5 000c50 0469abc1c Firmware Version: 0003HPM1 User Capacity: 500 107 862 016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Mon Apr 6 19:47:59 2020 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 103) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 099 082 006 Pre-fail Always - 77226584 3 Spin_Up_Time 0x0023 098 097 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 083 083 000 Old_age Always - 17670 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x002f 083 060 030 Pre-fail Always - 224240890 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15106 10 Spin_Retry_Count 0x0033 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 093 093 000 Old_age Always - 8058 183 Runtime_Bad_Block 0x0032 085 085 000 Old_age Always - 15 184 End-to-End_Error 0x0033 098 098 097 Pre-fail Always - 2 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 6556 188 Command_Timeout 0x0032 100 096 000 Old_age Always - 1606342279555 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 065 042 045 Old_age Always In_the_past 35 (0 193 35 25 0) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 349 192 Power-Off_Retract_Count 0x0022 094 094 000 Old_age Always - 12383 193 Load_Cycle_Count 0x0032 003 003 000 Old_age Always - 195313 194 Temperature_Celsius 0x0022 035 035 000 Old_age Always - 35 (0 3 0 0 0) 195 Hardware_ECC_Recovered 0x003a 114 099 000 Old_age Always - 77226584 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 099 097 000 Old_age Always - 40 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 5346 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 5346 occurred at disk power-on lifetime: 15104 hours (629 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da b8 ff ff ff 4f 00 00:00:09.693 READ DMA EXT 25 da c0 ff ff ff 4f 00 00:00:06.678 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.675 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.673 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.672 READ DMA EXT Error 5345 occurred at disk power-on lifetime: 15104 hours (629 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da c0 ff ff ff 4f 00 00:00:06.678 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.675 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.673 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.672 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.672 READ DMA EXT Error 5344 occurred at disk power-on lifetime: 15104 hours (629 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da b8 ff ff ff 4f 00 00:00:09.755 READ DMA EXT 25 da c0 ff ff ff 4f 00 00:00:06.740 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.729 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.727 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.726 READ DMA EXT Error 5343 occurred at disk power-on lifetime: 15104 hours (629 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da c0 ff ff ff 4f 00 00:00:06.740 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.729 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.727 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.726 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.725 READ DMA EXT Error 5342 occurred at disk power-on lifetime: 15104 hours (629 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da b8 ff ff ff 4f 00 00:00:09.783 READ DMA EXT 25 da c0 ff ff ff 4f 00 00:00:06.769 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.759 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.757 READ DMA EXT 25 da 08 ff ff ff 4f 00 00:00:06.755 READ DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed: read failure 90% 15101 503319336 # 2 Short offline Completed: read failure 90% 15101 503319336 # 3 Short offline Completed: read failure 90% 15101 503319336 # 4 Short offline Aborted by host 80% 10830 - # 5 Extended offline Interrupted (host reset) 00% 4911 - # 6 Extended offline Completed without error 00% 1216 - # 7 Short offline Completed without error 00% 1214 - # 8 Short offline Completed without error 00% 1214 - # 9 Short offline Completed without error 00% 4 - #10 Short offline Completed without error 00% 3 - #11 Short offline Completed without error 00% 3 - #12 Short offline Completed without error 00% 3 - #13 Short offline Completed without error 00% 2 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.